Back to search

Virginia Tech

Determining optimal load for a constant-load cycle ergometer test relative to isotonic leg strength

Abstract

dc:description.abstract

This study investigated the determination of an optimal resistive force for use during a short-term, high-intensity cycling power test. Twenty-four college females [age (yrs) x̄=22.0 ± 0.50; weight (kg) x̄=60.3 ± 1.46] gave consent and participated in a 1 repetition maximum (RM) test of the leg extensors and 5 maximal 15 s cycling tests using a modified Monark cycle ergometer. The 1 RM test was performed using a Nautilus leg extensor machine. Even increments between six to ten % 1RM test were utilized to determine the resistive force applied to the flywheel. The 5 tests were divided into a 2 testing sessions occurring at least 48 h apart. Each subject warmed-up at 50 - 60 rpms for 2 - 5 minutes without resistance prior to testing. Each test consisted of a maximal cycling bout of 15 s with 20 minutes rest between tests. The variables measured included peak power (PP), time to peak power (TTPP), power fatigue rate (PFR), power fatigue index (PFI), and average power (AP). These values were collected by a microcomputer interfaced with the cycle ergometer. In general, PP decreased at a resistance greater than 9 % 1RM. The average reported PP values were 363±15, 413±19, 465±19, 520±21, and 460±41 for loads 6 to 10 % 1RM respectively. Similar results were reported for AP. The differences in PP for loads between 8 and 10 % 1RM were statistically different. Results show that PP varies based on loads of % 1RM and the optimal range is between 8 and 10% 1RM.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Exercise Physiology
Department dc:contributor.department
Exercise Physiology
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1992

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wagner, Holly A.

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
etd-01242009-063426
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/40762

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Wagner, Holly A.. Determining optimal load for a constant-load cycle ergometer test relative to isotonic leg strength. masters thesis, Virginia Tech, 1992. http://hdl.handle.net/10919/40762