An experimental and analytic study of earth loads on rigid retaining walls

Abstract

dc:description.abstract

Experimental and analytic investigations were performed to examine the influences of wall height, backfill behavior, and compaction on the magnitudes of backfill loads on rigid retaining walls. Measurements of lateral and vertical backfill loads were made during tests using the Virginia Tech instrumented retaining wall facility. The tests were performed with two soils, moist Yatesville silty sand and dry Light Castle sand. Two hand-operated compactors, a vibrating plate compactor and a rammer compactor, were used to compact the backfill. The backfill height was 6.5 feet in all of the tests. Analyses of backfill loads were made using a compaction- induced lateral earth pressure theory and a vertical shear force theory. The compaction-induced lateral earth pressure theory was revised from a previous theory. The revisions improved the accuracy with which the theory models the hysteretic stress behavior of the backfill during compaction. The theory was also extended to include the pore pressure response of moist backfill in a rational manner. A vertical shear force theory was also developed during this research. The theory is based on consideration of backfill compressibility and mobilization of interface shear strength at the contact between the backfill and the wall. The theory provides a useful basis for understanding how wall height, backfill compressibility, wall-backfill interface behavior, and compaction-induced lateral pressures affect the vertical shear forces on rigid walls. Studies were also made to investigate the cause of erratic pressure cell readings. An important cause of drift in pressure cell readings was found to be moisture changes in the concrete in which the pressure cells were mounted. It was found that this problem could be mitigated by applying a water-seal treatment to the face of the wall. Both the vibrating plate compactor and the rammer compactor were instrumented to measure dynamic forces and energy transfer during compaction. The force applied by the vibrating plate compactor was about one-quarter of the manufacturer’s rated force. The force applied by the rammer compactor was about twice the manufacturer’s rated force. The transferred energy measurements provided a basis for relating laboratory and field compaction procedures.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Civil Engineering
Department dc:contributor.department
Civil Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1992

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Filz, George M.
Chair dc:contributor.committeechair
  • Duncan, James M.
Committee members dc:contributor.committeemember
  • Brandon, Thomas L.
  • Clough, G. Wayne
  • Kuppusamy, Thangavelu
  • Reddy, Junuthula N.

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
etd-05222007-091353
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/37882

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Filz, George M.. An experimental and analytic study of earth loads on rigid retaining walls. doctoral thesis, Virginia Tech, 1992. http://hdl.handle.net/10919/37882