Effects of Louver Length and Vortex Generators to Augment Tube Wall Heat Transfer in Louvered Fin Heat Exchangers

Abstract

dc:description.abstract

There are several different types of compact heat exchangers used in applications where small size and weight are required. One particular type of compact heat exchanger, the louvered fin heat exchanger, has been used heavily in the automotive and air conditioning industries. Over the last several decades, the majority of the work towards improving louvered fin exchanger efficiency has focused on designing more efficient fins by optimizing fin parameters like louver angle, fin pitch, louver pitch, and louver length. At this point in time, many improvements to standard louver geometry have been made, so other surfaces and methods of enhancing exchanger performance need to be studied if any significant future efficiency gains are to be expected. This thesis presents a detailed experimental study that has two major foci relative to the performance of the louvered fin compact heat exchanger. The first is to determine the effect of louver length on pressure drop and tube wall heat transfer, which is the primary heat transfer surface in the heat exchanger. The second is to augment tube wall heat transfer with the use of delta winglets placed on the fins near the tube wall. These studies were completed on a 20X scale model of a louvered fin exchanger with a fin pitch to louver pitch ratio of 0.76 and a louver angle of 27°, over a Reynolds number range based on louver pitch of 230 < ReLp < 1016. The three louver lengths evaluated were 100%, 82%, and 70% of the fin height and delta winglet experiments were performed for louver length to fin pitch ratios of 100% and 70%. Heat transfer results for the louver length tests show that decreasing louver length leads to increases in tube wall heat transfer of 0% to 50% depending on Reynolds number. Also, delta winglets placed on the fins near the tube wall have been shown to produce average tube wall heat transfer augmentations of up to 52%.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sanders, Paul Alan
Chair dc:contributor.committeechair
  • Thole, Karen A.
Committee members dc:contributor.committeemember
  • Vick, Brian L.
  • Huxtable, Scott T.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-09252005-221130
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/35189

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Sanders, Paul Alan. Effects of Louver Length and Vortex Generators to Augment Tube Wall Heat Transfer in Louvered Fin Heat Exchangers. masters thesis, Virginia Tech, 2005. http://hdl.handle.net/10919/35189