Misalignment Effects of the Self-Tracking Laser Doppler Vibrometer

Abstract

dc:description.abstract

There are many limitations to the current methods used to measure vibration on rotating structures. These limitations include physical flow blockages, relating the measurement spot to the structure rotation, data processing issues, and having to physically alter the engine. This work further describes aspects of a self-tracking laser vibrometry system that can be used to measure the vibrations of rotating structures. This method, if setup correctly, has the capability to overcome many of the limitations listed above. A study of all misalignment effects is presented in this thesis. The study consists of a parametric sensitivity analysis of misalignment variables, a parametric Monte Carlo analysis of misalignment variables, and a full interaction Monte Carlo analysis of misalignment variables. In addition, the results of the misalignment variable analyses were used to develop a self-tracker test rig for obtaining fan vibration from a Pratt and Whitney JT15D turbofan engine. A prototype this test rig was designed, built, and tested on the turbofan. It was found that in order to achieve acceptable amounts of position and velocity error using the self-tracker LDV system, very strict alignment of the optical equipment is necessary. Additionally, the alignment criteria can likely be achieved with the use of digitally controlled high precision linear motion equipment.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zima, Andrew David Jr.
Chair dc:contributor.committeechair
  • King, Peter S.
Committee members dc:contributor.committeemember
  • O'Brien, Walter F. Jr.
  • Wicks, Alfred L.

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-05102001-095500
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/32471

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Zima, Andrew David Jr.. Misalignment Effects of the Self-Tracking Laser Doppler Vibrometer. masters thesis, Virginia Tech, 2001. http://hdl.handle.net/10919/32471