Back to search

Virginia Tech

Reliability and Validity of Body Composition and Bone Mineral Density Measurements by DXA

Abstract

dc:description.abstract

Dual energy X-ray absorptiometry (DXA) has been well established in both clinical and research settings for measurement of bone mineral density (BMD), and is becoming more widely utilized for assessment of body composition. Reliability and validity are essential factors in both applications of this technique; however, neither have been confirmed for the QDR-4500A DXA at Virginia Tech. Therefore, measurements of the whole body (WB), lumbar spine (LS), total proximal femur (TPF) and total forearm (TF) were made in a group of young-adult males and females at two time-points, 5-7 days apart. Significant differences were not found in BMD (g/cm2) at these body sites with repeated measurements by DXA. Furthermore, measures of percent body fat (%BF), lean body mass (LBM), and fat mass (FM) by DXA were reliable. Validity of %BF by DXA was assessed from comparison to single-frequency bioelectrical impedance analysis (BIA). Significant differences were not found in measures of %BF by DXA and BIA. A second study investigated the reliability and validity of the QDR-4500A DXA in measurements of distal tibia (DT) BMD. Significant differences were not found between repeated measurements. Validity was established by a significant correlation between WB BMD and DT BMD. A third study examined the influence of navel jewelry on the accuracy of LS DXA measurements. Repeated measurements with a spine phantom revealed that both a navel ring and a barbell produced significantly greater measures of LS BMD compared to the spine phantom alone. Manual correction of navel jewelry did not eliminate BMD inaccuracies. Data from these studies confirmed that the QDR-4500A DXA at Virginia Tech was a reliable and valid device in measurement of WB, LS, TPF, TF and DT BMD, as well as %BF, LBM, and FM. In addition, effects of navel jewelry on LS BMD have been recognized. Further studies investigating the reliability and validity of DT BMD measures as well as effects of different types, gauges, and shapes of body jewelry on BMD measures in human subjects are warranted.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Human Nutrition, Foods, and Exercise
Department dc:contributor.department
Human Nutrition, Foods, and Exercise
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zack, Melissa Kareen
Chair dc:contributor.committeechair
  • Nickols-Richardson, Sharon M.
Committee members dc:contributor.committeemember
  • Poole, Kathleen P.
  • Herbert, William G.

Subjects

dc:subject × 10

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-04172002-123509
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/31741

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Zack, Melissa Kareen. Reliability and Validity of Body Composition and Bone Mineral Density Measurements by DXA. masters thesis, Virginia Tech, 2003. http://hdl.handle.net/10919/31741