Water Treatment: Fundamentals and Practical Implications of Bubble Formation

Abstract

dc:description.abstract

Water utilities can experience problems from bubble formation during conventional treatment, including impaired particle settling, filter air binding, and measurement as false turbidity in filter effluent. Coagulation processes can cause supersaturation and bubble formation by converting bicarbonate alkalinity to carbon dioxide by acidification. A model was developed to predict the extent of bubble formation during coagulation which proved accurate, using an apparatus designed to physically measure the actual volume of bubble formation. Alum acted similar to hydrochloric acid for initializing bubble formation, and higher initial alkalinity, lower final solution pH, and increased mixing rate tended to increase bubble formation. Lastly, the protocol outlined in Standard Methods for predicting the degree of supersaturation was examined, and when compared to this work, the Standard Methods approach produces an error up to 16% for conditions found in water treatment. Air entrainment and ozonation are the key causes of dissolved gas supersaturation and eventual bubble formation in water treatment plants. Total dissolved gas probes (TDGP) are now available to directly measure supersaturation and have many advantages compared to conventional techniques. Bubble formation during coagulation-flocculation hindered particle sedimentation, producing settled turbidities double that of solutions without dissolved gases. In a filtration study, run time to one half of initial flow was decreased by 54% when the source water was increased from 0.1 to 0.2 atm supersaturation. Indeed, even at 0.05 atm supersaturation, run length was only 21 hours in solutions without added particulate matter. A case study confirmed that bubble formation can interfere with coagulation and filtration processes at conventional treatment plants.

Degree

thesis:*
Name thesis:degree_name
Master of Engineering
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Environmental Planning
Department dc:contributor.department
Environmental Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2000

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Scardina, Robert P.
Chair dc:contributor.committeechair
  • Edwards, Marc A.
Committee members dc:contributor.committeemember
  • Little, John C.
  • Knocke, William R.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-02242000-20530043
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/31332

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Scardina, Robert P.. Water Treatment: Fundamentals and Practical Implications of Bubble Formation. masters thesis, Virginia Tech, 2000. http://hdl.handle.net/10919/31332