Development of a Direct-Measurement Thin-Film Heat Flux Array

Abstract

dc:description.abstract

A new thin film heat flux array (HFA) was designed and constructed using a series of nickel/copper thermocouples deposited onto a thin Kapton® polyimide film. The HFA is capable of withstanding temperatures up to 300 °C and produces signals of 42 μV/(W/cm²). As a result of its thin film construction, the HFA has a first order time constant of 32 ms. Calibrations were completed to determine the gage's output as well as its time response. In order to measure the signal from the HFA amplifiers were designed to increase the magnitude of the voltage output. An example case is given where the HFA is used in an experiment to correlate time-resolved heat flux and velocities.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ewing, Jerrod Albert
Chairs dc:contributor.committeechair
  • Diller, Thomas E.
  • Vlachos, Pavlos P.
Committee member dc:contributor.committeemember
  • Huxtable, Scott T.

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-01122007-115434
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/30918

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Ewing, Jerrod Albert. Development of a Direct-Measurement Thin-Film Heat Flux Array. masters thesis, Virginia Tech, 2006. http://hdl.handle.net/10919/30918