Evaluation of a Permittivity Sensor for Continuous Monitoring of Suspended Sediment Concentration

Abstract

dc:description.abstract

According to the US Environmental Protection Agency (USEPA) sediment is a leading cause of water quality impairment (US EPA, 2002). The annual costs of sediment pollution in North America alone are estimated to range between $20 and $50 billion (Pimentel et al., 1995; Osterkamp et al, 1998, 2004). Due to the large spatial and temporal variations inherent in sediment transport, suspended sediment measurement is challenging. The overall goal of this research was to develop and test an inexpensive sensor for continuous suspended sediment monitoring in streams. This study was designed to determine if the gain and phase components of permittivity could be used to predict suspended sediment concentrations (SSC). A bench-scale suspension system was designed and tested to guarantee that there were no significant differences in the sediment suspension vertically or horizontally within the system. This study developed prediction models for SSC with input variables of temperature, specific conductivity, and gain and/or phase at multiple frequencies. The permittivity sensor is comprised of an electrode, power source, and a control box or frequency generator. Fixed and mixed effect, multiple, linear regression models were created and compared for target frequencies. However, it was not possible to meet the normality requirements for prediction accuracy. Partial Least Squares (PLS) regression techniques were also applied to gain and phase data for 127 of the 635 frequencies. The three models with the lowest error between predicted and actual values of SSC for validation were further tested with nine levels of independent validation data. The largest model error (error>50%) occurred for the top three models at 0 and 500 mg/L. At the higher concentrations error varied from 1-40%. Once the treatment levels, of the independent validation data set, were near 1000 mg/L the prediction accuracy increased for the top three models. Model 3A, a phase based model, preformed the best. Model 3A was able to predict six of the nine independent validation treatment levels within 300 mg/L. Future research will provide additional laboratory and field testing of the prototype sensor.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Biological Systems Engineering
Department dc:contributor.department
Biological Systems Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Utley, Barbra Crompton
Chair dc:contributor.committeechair
  • Wynn-Thompson, Theresa
Committee members dc:contributor.committeemember
  • Zipper, Carl E.
  • Diplas, Panos
  • Hession, W. Cully
  • Zhang, Naiqian
  • Persaud, Naraine

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-11132009-165802
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/29570

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Utley, Barbra Crompton. Evaluation of a Permittivity Sensor for Continuous Monitoring of Suspended Sediment Concentration. doctoral thesis, Virginia Tech, 2009. http://hdl.handle.net/10919/29570