This study presents an evaluation of the Bird Mark 8 Respirator with J Circuit in neonatal application. The system was studied with special attention to the desirability of its possible application in the treatment of a respiratory ailment of newborn infants called hyaline membrane disease. The project involved the determination of response time of the respirator and blood gas characteristics in rabbits after ventilation by the equipment. Rabbits were used in the experiment because their respiratory behavior resembles that of new-born infants with respiratory distress. The respiration of rabbits was assisted with air supplied to the respirator at 50 p.s.i. Average response times (minimum of 114 milliseconds, for the case of the rabbit tripping the respirator, with 1 centimeter of water negative pressure in the delivery line), were determined to be in excess of the 20-30 milliseconds maximum limit that may be tolerated by the infant in the treatment of this disease. Blood gas characteristics of the rabbits ventilated for 2 hours with the respirator showed significant increases in the partial pressure of carbon dioxide and significant decreases in the partial pressure of oxygen and pH levels, as compared with the normal blood gas characteristics. These changes are considered undesirable. From this study it is believed that the respirator does not provide the adequate assistance to respiration required for the treatment of infants afflicted with respiratory distress.

Degree

thesis:*
Name thesis:degree_name
M. S.
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Industrial Engineering
Department dc:contributor.department
Industrial Engineering
Grantor dc:publisher
Virginia Polytechnic Institute
Year dc:date.issued
1967

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yeeda, David

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/10919/118876
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/118876

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Yeeda, David. Evaluation of the Bird Mark 8 respirator with J circuit for neonatal application. masters thesis, Virginia Polytechnic Institute, 1967. https://hdl.handle.net/10919/118876