Back to search

Virginia Tech

Use of Glucose Monitoring Systems in Horses

Abstract

dc:description.abstract

Traditional methods of blood glucose monitoring involve obtaining samples for measurement via laboratory methodology or point of care devices and require invasive collection techniques such as capillary stick, venipuncture, or the placement of intravenous catheters. Limitations of traditional methods include the limited information provided by intermittent testing and the stress associated with restraint and discomfort experienced by patients. The snapshot nature of the provided information restricts a clinician's ability to truly monitor trends in glucose concentrations over an extended period of time, influencing clinical decision making. The stress of invasive sampling can cause stress hyperglycemia in many veterinary species, complicating interpretation. Continuous interstitial glucose monitoring technology is widely used in the human medical field due to the expansive information provided in a minimally invasive manner. In recent years, the device technology has advanced and cost has improved, prompting application of these devices into the veterinary sector. Studies have shown good agreement between newer glucose monitoring systems and traditional methods in small animal patients with diabetes mellitus, allowing veterinarians to obtain comprehensive glucose data with minimal stress and discomfort to the patient. However, information regarding the use of this new technology in equine medicine is limited. The following study describes the evaluation of two widely available glucose monitoring systems, the Dexcom G6 and the FreeStyle Libre, in healthy adult horses.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biomedical and Veterinary Sciences
Department dc:contributor.department
Biomedical and Veterinary Sciences
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Malik, Caitlin Elyse
Chair dc:contributor.committeechair
  • McKenzie, Harold C.
Committee members dc:contributor.committeemember
  • Wong, David Michael
  • Wilson, Katherine E.

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:35315
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/111682

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Malik, Caitlin Elyse. Use of Glucose Monitoring Systems in Horses. masters thesis, Virginia Tech, 2022. http://hdl.handle.net/10919/111682