Back to search

Virginia Polytechnic Institute

The effect of magnesium ions on the current efficiency of magnesium anodes used as cathodic protectors

Abstract

dc:description.abstract

The object of this investigation was to determine, if possible, whether or not the magnesium ion concentration in the backfill has a significant effect upon the current efficiency of a pure magnesium anode when used to protect a steel cathode. Accordinging to H.A. Robinson, there should normally be no effect, but he indicated that there is room for doubt in some cases. It may be concluded, from the results obtained in this experimental work, that the current efficiency of magnesium anodes, when used as cathodic protectors of steel, is generally unaffected by changes in the concentration of magnesium sulfate in the backfill. It may be further stated that the presence of manganese ion also has no effect upon the current efficiency. The results indicate the possibility that current efficiency is appreciably affected by changes in the current density at the anode. It is suggested that further work be done in the study of this effect. It is further suggested that a wide variety of backfill conditions, for example, soils of different pH, be used in conjunction with this study.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Chemistry
Department dc:contributor.department
Chemistry
Grantor dc:publisher
Virginia Polytechnic Institute
Year dc:date.issued
1947

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hawxhurst, Daniel Smith

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10919/110240
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/110240

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Hawxhurst, Daniel Smith. The effect of magnesium ions on the current efficiency of magnesium anodes used as cathodic protectors. masters thesis, Virginia Polytechnic Institute, 1947. http://hdl.handle.net/10919/110240