Back to search

Virginia Tech

Trace Level Impurity Quantitation and the Reduction of Calibration Uncertainty for Secondary Ion Mass Spectrometry Analysis of Niobium Superconducting Radio Frequency Materials

Abstract

dc:description.abstract

Over the last decade, the interstitial alloying of niobium has proven to be essential for enabling superconducting radiofrequency (SRF) cavities to operate more efficiently at high accelerating gradients. The discovery of "nitrogen doping" was the first readily accessible avenue of interstitial alloying in which researchers saw an increase in cavity performance. However, the serendipitous nature of the discovery led to additional research to fundamentally understand the physics behind the increase in cavity performance. This knowledge gap is bridged by materials characterization. Secondary ion mass spectrometry (SIMS) is a characterization technique which has become a staple of SRF cavity characterization that details elemental concentration profiles as a function of depth into the niobium surface with submicron resolution. SIMS has been widely used by the semiconductor industry for decades but has found less application in other fields due to the difficulty to produce reproducible data for polycrystalline materials. Much effort has been given to reduce the uncertainty of SIMS results to as low as 1% - 2% for single crystals. However, less attention has been given to polycrystalline materials with uncertainty values reported between 40% - 50% The sources of uncertainty were found to be deterministic in nature and therefore could be mitigated to produce reliable results. This dissertation documents the efforts to reduce SIMS method uncertainty which has been further used to solve mysteries regarding the characterization of SRF cavities which include predictive modeling of oxygen diffusion as well as the identification of contaminants resulting from cavity furnace treatments.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Materials Science and Engineering
Department dc:contributor.department
Materials Science and Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Angle, Jonathan Willis
Chair dc:contributor.committeechair
  • Kelley, Michael J.
Committee members dc:contributor.committeemember
  • Stevie, Fred A.
  • Murayama, Mitsuhiro
  • Reece, Charles E.
  • Reynolds, William T. Jr.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • Creative Commons Attribution 4.0 International
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:34252
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/109615

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Angle, Jonathan Willis. Trace Level Impurity Quantitation and the Reduction of Calibration Uncertainty for Secondary Ion Mass Spectrometry Analysis of Niobium Superconducting Radio Frequency Materials. doctoral thesis, Virginia Tech, 2022. http://hdl.handle.net/10919/109615