Back to search

Virginia Tech

A Method for Measuring Spatially Varying Equivalence Ratios with Application to Thermoacoustics

Abstract

dc:description.abstract

Computed tomography for flame chemiluminescence emissions allows for 3D spatially resolved flame measurements to be acquired using a series of discrete viewing angle camera images. To determine fuel/air ratios, the ratio of excited radical species (OH*/CH*) emissions using chemiluminescence can be employed. Following the process of high-resolution tomography reconstructions in this work allowed for flame tomography coupled with chemiluminescence emissions to be used for spatially resolved phase averaged equivalence ratio measurements. This is important as variations in local equivalence ratios can have a profound effect on flame behavior including but not limited to thermoacoustic instability, NOx and CO formation, and flame stabilization. Local equivalence ratios are determined from a OH*/CH* ratio of tomographically reconstructed intensity fields and relating them to equivalence ratio. The correlation of OH*/CH* to equivalence ratio is derived from an axisymmetric, commercially available flat flame burner (Holthuis and Associates Burner). To relate intensity field imaging (camera coordinate system) during the tomographic reconstruction to the real-world coordinate system of the burner a calibration procedure was performed and then validated. A calibration plate with 39 non-coplanar points was used in this procedure. It was then validated by comparing the Abel inverted flame images of the axisymmetric Holthuis and Associates burner with the tomographic reconstructed images. Results show a successful tomographic reconstruction of thermoacoustic self-excited cycle concluding equivalence ratio fluctuations coinciding with the 1st dominate frequency of the pressure fluctuations and influenced by a 2nd harmonic frequency.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hugger, Blaine Thomas
Chair dc:contributor.committeechair
  • Meadows, Joseph
Committee members dc:contributor.committeemember
  • Ng, Wing Fai
  • Lowe, K. Todd

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:33027
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/107111

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Hugger, Blaine Thomas. A Method for Measuring Spatially Varying Equivalence Ratios with Application to Thermoacoustics. masters thesis, Virginia Tech, 2021. http://hdl.handle.net/10919/107111