Back to search

Virginia Polytechnic Institute

An investigation of some design factors of a steam jet refrigeration unit

Abstract

dc:description.abstract

A series of tests was run to determine the performance characteristics of the 2-1/2 ton steam jet refrigeration unit. The first series of tests was run to determine the nozzle position relative to the throat of the diffuser at which best performance was obtained. This series included tests with two methods of introducing the warm water into the evaporator, namely by spraying the warm water into the evaporator by means of commercial spray nozzles and by spraying the warm water into the evaporator through small holes in a straight piece of pipe. A series of tests was run to determine the effect of the evaporator water level on performance. A series of tests was also run with inlet steam pressures lower and higher than design in combination with outlet pressures at and lower than design. Lastly, one test was run in an effort to reduce the amount of liquid carryover into the ejector. From the results of the above tests the following was concluded: 1. Use of a 62% entrainment efficiency and a 65% diffuser efficiency to give a greater steam flow rate did not enable the design capacity to be met. 2. Best performance of the unit was obtained with the nozzle exit 7-1/2 inches from the entrance to the diffuser throat. 3. Better performance was obtained from the unit by introducing the wara water into the evaporator by means of the commercial spray nozzles than was obtained by introducing the warm water into the evaporator by means of small hole in a straight pipe. 4. Lowering the evaporator water level did not effect performance of the unit greatly. However, control of the unit was greatly enhanced by using a low evaporator water level. 5. Performance of the unit was unstable at inlet steam pressures above design and outlet pressure below design. The capacity of the unit dropped sharply under these condition 6. The design evaporator outlet velocity was too high to enable a sufficiently large amount of liquid carryover to be baffled out. 7. The compression process in the diffuser did not occur as assumed in the design procedure. 8. The throat area of the diffuser should be increased to reduce the fluid velocity in the throat and thereby improve performance of the unit. This is necessary to make the normal shock occur at the throat section of the diffuser.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Polytechnic Institute
Year dc:date.issued
1954

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Brehm, Robert Luther

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10919/104266
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/104266

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Brehm, Robert Luther. An investigation of some design factors of a steam jet refrigeration unit. masters thesis, Virginia Polytechnic Institute, 1954. http://hdl.handle.net/10919/104266