Measurements and Predictions of the Heat Transfer at the Tube-Fin Junction for Louvered Fin Heat Exchangers

Abstract

dc:description.abstract

Compact heat exchangers are usually characterized by a large heat transfer surface per unit of volume. These characteristics are useful when thermal energy between two or more fluids must be exchanged without mixing. Most compact heat exchangers are liquid-to-air heat exchangers, with approximately 85% of the total thermal resistance occurring on the air side of the heat exchanger. To reduce the space and weight of a compact heat exchanger, augmentation strategies must be proposed to reduce the air side resistance. However, before any strategies to augment the air side heat transfer can be proposed, a thorough insight of the current mechanisms that govern air side heat transfer is required. The tube wall heat transfer results presented in this paper were obtained both experimentally and computationally for a typical compact heat exchanger design. Both isothermal and constant heat flux tube walls were studied. For the experimental investigation, a scaled-up model of the louvered fin-tube wall was tested in a flow facility. Although computational results for the isothermal tube wall are shown, control of the experimental isothermal tube wall proved to be unrealistic and only heat transfer measurements along the constant heat flux tube wall were made. For the constant heat flux tube wall, reasonable agreement has been achieved between the measurements and the steady, three-dimensional computational predictions. The results of the study showed that high heat transfer coefficients existed at the entrance to the louver array as well as in the louver reversal region. Vortices created at the leading edge of the louvers augmented heat transfer by thinning the tube wall boundary layer. Results indicate that an augmentation ratio of up to 3 times can occur for a tube wall of a louvered fin compact heat exchanger as compared to a flat plate.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Ebeling, Christopher P.
Chair dc:contributor.committeechair
  • Thole, Karen A.
Committee members dc:contributor.committeemember
  • Vick, Brian L.
  • Tafti, Danesh K.

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-06232003-172030
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/10140

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Ebeling, Christopher P.. Measurements and Predictions of the Heat Transfer at the Tube-Fin Junction for Louvered Fin Heat Exchangers. masters thesis, Virginia Tech, 2003. http://hdl.handle.net/10919/10140