Virginia Commonwealth University
Esthetic Posterior Stainless Steel Crowns and their Relative Shear Strengths
Abstract
dc:description.abstractPurpose: The purpose of this study was to evaluate esthetic posterior stainless steel crowns (EP-SSC) and compare their relative shear strengths.Methods: Sixty EP-SSC were compared. 15 crowns from NuSmile® Primary Crowns, Kinder Krowns, and Dental Innovators 1UP and EC Crowns were studied. The crowns were cemented to a typodont tooth then thermally cycled in water baths to simulate oral conditions. Shear strengths were evaluated by subjecting these crowns to simulated forces of occlusion.Results: The force required to cause shearing of the esthetic facings was statistically significant. With the 1UP crown being significantly weaker than the other crowns tested. Conclusion: The 1 UP crowns failed at lower levels of force than the other types of EP-SSC. The shear strengths for the three other crown types were not statistically different from each other. The esthetic facings do not likely fail from the single point load of a child's bite.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Pediatric Dentistry
- Year dc:date.available
- 2008
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Carmichael, Lonny Dale
- Contributors dc:contributor
-
- Dr. Tegwyn H. Brickhouse
Subjects
dc:subject × 9Rights
dc:rights- Statement dc:rights
-
- © The Author
Identifiers
dc:identifier.*- Identifier
- https://scholarscompass.vcu.edu/etd/937
- OAI identifier oai:identifier
- oai:scholarscompass.vcu.edu:etd-1936