University of Central Florida
Application Of In Vivo Flow Profiling To Stented Human Coronary Arteri
Abstract
dc:description.abstract<p>The study applies in vivo technique for profiling hemodynamics and wall shear stress (WSS) distribution in human coronary arteries. The methodology involves fusion of 2D Intra Vascular Ultra Sound and Bi-plane angiograms to reproduce the 3D arterial geometry. This geometry is then used in a Computational Fluid Dynamics (CFD) module for flow modeling. The Walburn and Schneck constitutive relation was used to represent the non-Newtonian blood rheology. The methodology is applied to study the relationship between WSS and Neointimal Hyperplasia (NIH) in two groups of diabetic patients after being treated separately with bare metal stents (BMS) and Sirolimus Eluting Stents (SES). The stent assignments were blinded until the end of the study. The study was repeated for the patients after 9 months. The predicted WSS ranged from (0.1- 8 N/m2) and was categorized into five classes: low ( < 1 N/m2); low-normal (1-2 N/m2); normal (2-3 N/m2); high-normal (3-4 N/m2); high ( > 4 N/m2). The results indicate NIH in 5 of the patients treated with BMS and none in SES cases. These results correlate with our predicted WSS distribution.</p>
Degree
thesis:*- Grantor dc:publisher
- University of Central Florida
- Year
- 2004
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Nanda, Hitesh
- Contributors dc:contributor
-
- Ilegbusi, Olusegun
Subjects
dc:subject × 8Rights
- Language dc:language
- English
Identifiers
dc:identifier.*- Identifier
- CFE0000275
- OAI identifier oai:identifier
- oai:stars.library.ucf.edu:etd-1215