Back to search

Texas A & M University

Development of an Encapsulation Strategy for an Implantable Optical Glucose Sensing Technology Compatible with a Self-Cleaning Membrane

Abstract

dc:description.abstract

The concerning rate of diabetes mellitus prevalence and its associated chronic complications accentuates the urgency for continuous glucose monitoring. Optical techniques, especially fluorescence-affinity assays, offer a strategy that transcends current transcutaneous sensors by enabling subcutaneous implantation and interrogation. Biosensors can initiate an immune response that ultimately leads to a dense fibrous capsule surrounding the sensor. This biological interference, termed “biofouling,” severely limits implantable sensor lifetimes by slowing analyte diffusion and decreasing optical signal propagation. In an effort to control biofouling, a thermoresponsive, “self-cleaning,” hydrogel membrane based on poly(N-isopropylacrylamide) (PNIPAAm) has been proposed. Further, a continuous glucose monitoring system based on a competitive binding assay using Concanavalin A (ConA) as a component in a Förster resonance energy transfer (FRET) approach is being developed for encapsulation within the thermoresponsive hydrogel. In this research, a double network nanocomposite PNIPAAm (DNNC) hydrogel’s glucose diffusion, thermosensitivity, cytocompatibility, in vitro cellular release, and in vivo compatibility and efficacy were thoroughly investigated. Further, an encapsulation strategy was developed for retaining the glucose assay within the hydrogel and yet allowing glucose diffusion. The methods and systems for obtaining the in vitro and in vivo results of the hydrogel are presented along with the glucose encapsulation strategies. In general, the research showed that the hydrogel could adequately diffuse glucose at temperatures associated with subcutaneous implantation, maintain a stable thermal cycling profile, promote cellular release without toxic effects in vitro, and decrease the extent of biofouling in vivo. Furthermore, the hydrogel revealed its feasibility to be embedded with layer-by-layer (LbL) microsphere assemblies, which exhibited the ability to encapsulate the components of a competitive binding glucose assay. Overall, the results of this research demonstrate that the hydrogel combined with the encapsulated glucose assay is a promising approach for an implantable continuous glucose monitoring biosensor.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
Doctoral
Discipline thesis:degree_discipline
Biomedical Engineering
Grantor
Texas A & M University
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Abraham, Alexander Anil
Advisors dc:contributor.advisor
  • Coté, Gerard L
  • Grunlan, Melissa A
Committee members dc:contributor.committeemember
  • McShane, Michael J
  • Pishko, Michael V.
  • Clubb, Jr., Fred J

Subjects

dc:subject × 9

Rights

Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1969.1/174806

Chain of custody

source
Harvested from
Texas A&M University
Base URL
oaktrust.library.tamu.edu/server/oai/request
Last updated
2026-08-21
Source record
OAI-PMH GetRecord
citation

Abraham, Alexander Anil. Development of an Encapsulation Strategy for an Implantable Optical Glucose Sensing Technology Compatible with a Self-Cleaning Membrane. Doctoral thesis, Texas A & M University, 2015. https://hdl.handle.net/1969.1/174806