Abstract

dc:description.abstract

<p>Intracortical microelectrodes are devices used in brain-computer interfaces (BCI) to help regain lost motor, sensory, and cognitive functions of individuals with neurological disorders. However, the long-term performance of microelectrode arrays is hampered by a series of inflammatory tissue responses. The consequence of the inflammatory response is the formation of a dense astroglial sheath around the vicinity of the electrode, impeding the electrical conduction between the electrode and neurons. Furthermore, due to the cascade of neuroinflammatory events, the number of neurons is significantly reduced near the electrode, manifested by decrease in signal-to-noise ratio (SNR) and the yield of electrodes. Over time, these issues eventually lead to the functional failure of the implant.</p> <p>This study aims to investigate mechanical intervention strategies to mitigate the effect of the biological response and prolong the lifetime of the implanted microelectrodes. First, the longitudinal recording performance of a modified site geometry was evaluated. With planar silicon microelectrodes, sites placed on the edge outperformed the sites placed on the center, demonstrated by increased number of detectable single units with enhanced longevity. Second, the stress-strain induced biological response was studied using various flexible electrodes. Flexible electrodes indeed reduced the magnitude of the biological response than the traditional stiff silicon electrodes. Past a certain flexibility level, however, the biological response did not reduce over less soft electrodes, suggesting a flexibility threshold model. Finally, the biological response of electrodes dip-coated with polyethylene glycol (PEG) was evaluated to resolve a potential confound of PEG-coating used for inserting flexible electrodes. Results suggest that dip-coating with PEG do not significantly alter the inflammatory biomarker profiles around the device. Overall, findings from assessing the above mentioned intervention strategies will help devising a complex multimodal solution for prolonging the lifetime of neural implants.</p>

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy (PhD)
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Biomedical Engineering
Year
2016

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lee, Heui Chang
Contributors dc:contributor
  • Kevin J. Otto
  • Edward L/ Barlett
  • Michael G. Heinz
  • Kinam Park

Subjects

dc:subject × 7

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:docs.lib.purdue.edu:open_access_dissertations-2180

Chain of custody

source
Harvested from
Purdue University
Base URL
docs.lib.purdue.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Lee, Heui Chang. Device design factors for enhancing the functionality of chronic intracortical microelectrodes. Dissertation thesis, 2016. https://docs.lib.purdue.edu/open_access_dissertations/963