Back to search

Massachusetts Institute of Technology

Impact of intrafractional prostate motion on the accuracy and efficiency of prostate cancer treatment on CyberKnife radiotherapy

Abstract

dc:description.abstract

One of the most common treatments for men with localized prostate cancer is radiation therapy, which involves delivering small doses of radiation to the prostate for an extended period of time. Stereotactic-body radiation therapy (SBRT) is a form of radiotherapy that delivers increased dosage to the prostate with more precision. The results are shorter treatment times, increased effectiveness, and less toxicity to surrounding tissue. However, the prostate has been found to move around during treatment (intrafraction) and between treatments (interfraction). With greater precision, there is a greater risk of missing the target while the prostate is moving. This study assesses the impact of intrafractional prostate motion on the accuracy and efficiency of SBRT on CyberKnife. Prostate tracking log files were acquired from 6 patients with prostate cancer, which comprises18 SBRT fractions and 1,892 X-ray image registrations. Each image contains real-time prostate motion in 6D. The data were compared against clinically used margins to identify periods of large prostate motion during treatment. Results indicate significant periods of prostate motion, with the greatest movement occurring in anterior-posterior translation (6.2% outside margin) and pitch rotation (4.3% outside margin). The percentage of prostate motion beyond margins varied among patients, with an average of 12.8% outside clinical margins and 36.0% outside hypothetically reduced margins. The treatment time for each fraction was also recorded to quantify the efficiency of CyberKnife delivery. Because of motion-related delays, optimal setup of 5-15 minutes was seen in only 50% of the fractions, and optimal beam delivery times of 30-40 minutes in 44% of fractions. Thus, results suggest that treatment accuracy and efficiency were negatively affected by the occurrence of large prostate motion. Techniques that immobilize the prostate during treatment may be considered to reduce intrafractional prostate motion and ensure greater accuracy and efficiency of prostate cancer SBRT.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • De Armas, Ricardo Eduardo
Advisor dc:contributor.advisor
  • Barbara Hughey.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/98920
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/98920

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

De Armas, Ricardo Eduardo. Impact of intrafractional prostate motion on the accuracy and efficiency of prostate cancer treatment on CyberKnife radiotherapy. Massachusetts Institute of Technology, 2015. http://hdl.handle.net/1721.1/98920