Back to search

Massachusetts Institute of Technology

Electromechanical systems to enhance the usability and diagnostic capabilities of ultrasound imaging

Abstract

dc:description.abstract

Ultrasound is used extensively in medicine to non-invasively examine soft tissues. Compared to computed-tomography (CT) scanning or X-ray imaging, ultrasound is lower-cost, more portable, real time, and subjects neither the caregiver nor the patient to potentially harmful ionizing radiation, which makes it the imaging modality of choice for many medical applications. Common uses include fetal, vascular, and musculoskeletal imaging, as well as biopsy needle insertion guidance. With 165 million ultrasound exams conducted in the United States annually, and an annual US market of $1.3 billion, improvements to the usability and diagnostic capabilities of ultrasound imaging could lead to significant improvements in medical care. Ultrasound is unique because it generally requires significant contact force with the patient. This has a number of important consequences. The contact forces exerted by the ultrasound probe are generally not known, resulting in images that are acquired at non-repeatable levels of compression, which makes sequentially-acquired ultrasound images difficult to compare and reproduce. Contact force has also been implicated as a major risk factor in work-related musculoskeletal disease (WRMSD) amongst ultrasonographers; currently, clinical reports indicate that nearly 90% of sonographers scan in pain. This thesis explores the mechanical design and experimental evaluation of three novel electro-mechanical systems that could be used to enhance the usability and diagnostic capabilities of ultrasound by measuring and/or controlling probe acquisition state (i.e., contact forces, torques, and angles of orientation). The first system, a hand-held servo-driven ball screw stage, improves image repeatability by applying a constant, programmable contact force between the probe and the patient, and attenuates hand tremors by a factor of 10. The second system, a force/torque-measuring ultrasound probe, was used in the first rigorous clinical study to characterize contact forces and torques applied during abdominal scanning. The third device, driven by a voice coil motor, enables high-bandwidth constant force scanning, and was used to measure the elastic modulus of tissue-an indicator of tissue health-at repeatable pre-load forces.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2014

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Gilbertson, Matthew Wright
Advisor dc:contributor.advisor
  • Brian Anthony.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/96459
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/96459

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Gilbertson, Matthew Wright. Electromechanical systems to enhance the usability and diagnostic capabilities of ultrasound imaging. Massachusetts Institute of Technology, 2014. http://hdl.handle.net/1721.1/96459