Method and device for the detection and characterization of inhomogeneities of the prostate : the Quantitative Digital Rectal Exam (QDRE)

Abstract

dc:description.abstract

Prostate cancer is the most common cancer diagnosed in American males. However, current methods of screening for prostate cancer have low sensitivity and specificity for diagnosing patients with prostate cancer. A new methodology of screening for prostate cancer was formulated by developing a method and device to quantify the traditional digital rectal exam. The Quantitative Digital Rectal Exam (QDRE) measures the relative compliance at discrete locations on the posterior surface of the prostate. The Test Head of the QDRE indents the prostate and measures the pressure distribution across a rigid disk using an matrix of pressure transducers. The position of the Test Head is tracked by the Location Tracking System. The Mapping Algorithm analyzes each Test Head measurement and the position information recorded by the Location Tracking System, and generates a map showing magnitudes and locations of relative compliance across the measured surface of the prostate. A proof of concept test used a mock-up of the Test Head, a mechanical Location Tracking System and a rudimentary Mapping Algorithm to examine a clinical model of the prostate which had one nodule. The results were presented as a map of the measured surface of the prostate model, and results showed the size of the nodule (6.4 mm in diameter) and the relative compliance of the nodule (0.08 relative to the healthy tissue of the model), as well as the location within the measured surface.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
1999

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Morris, Stacy J., 1974-
Advisor dc:contributor.advisor
  • Ernest G. Cravalho.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/9061
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/9061

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Morris, Stacy J., 1974-. Method and device for the detection and characterization of inhomogeneities of the prostate : the Quantitative Digital Rectal Exam (QDRE). Massachusetts Institute of Technology, 1999. http://hdl.handle.net/1721.1/9061