Back to search

Massachusetts Institute of Technology

Experimental and gyrokinetic studies of impurity transport in the core of Alcator C-Mod Plasmas

Abstract

dc:description.abstract

Using a unique set of diagnostics and modeling tools, a comprehensive study of impurity transport was performed on Alcator C-Mod L-mode discharges. A new, multi-pulse laser blow-off system was designed and constructed to introduce trace amounts of non-recycling, non-intrinsic, impurities in the plasma edge. This system was coupled with an x-ray crystal spectrometer, a single chord x-ray/ultraviolet spectrometer, and measurement of the laser blow-off neutral source at the plasma edge to provide full, time-evolving, radial profiles of a single impurity charge state. An iterative X2 minimization scheme was created to infer the experimental impurity transport coefficients and their uncertainty by minimizing the difference in the measured and STRAHL simulated emission. These measurements and data analysis methodology allowed for determination of impurity transport coefficient profiles with realistic errors from 0.0 </= r/a </= 0.6. The gyrokinetic co(le, GYRO, was use to analyze the same discharges. Motivated by linear stability analysis and a rigorous assessment of simulation sensitivities, nonlinear gyrokinetic simulations were performed such that small modifications of the Ion Temperature Gradient (ITG) drive term, a/LT, were made to match the simulated ion heat flux, Qj. to the experimental value. These simulations demonstrated simultaneous, quantitative agreement with experiment across the simulation domain in the ion heat and impurity particle transport channels, and indicated the possibility of missing electron dynamics from the nonlinear gyrokinetic simulation. A study of Ip scaling used four discharges, constituting a scan of I, from 0.6 to 1.2 MA. These discharges displayed a clear reduction of the experimental impurity diffusion and inward convection, allowing for qualitative and quantitative comparison of experimental with gyrokinetic simulation. Linear stability analysis and high fidelity, global (0.29 </= r/a </= 0.62), nonlinear GYRO simulation of ion scale turbulence (kop, </= 1.15) were performed on these discharges with the result that nonlinear gyrokinetic simulation was generally able to reproduce both quantitative values and trends for the measured decrease in impurity diffusion and inward convection observed experimentally. Initial analysis of three discharges operated at various levels of ICRH input power displayed a reduction of the experimental impurity diffusion coefficient with input power. An in-depth linear stability analysis suggests a transition of the turbulence character (ITG to TEM) with input power which may explain changes in the measured diffusion.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Nuclear Science and Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Howard, Nathaniel Thomas
Advisor dc:contributor.advisor
  • Martin Greenwald.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/76920
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/76920

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Howard, Nathaniel Thomas. Experimental and gyrokinetic studies of impurity transport in the core of Alcator C-Mod Plasmas. Massachusetts Institute of Technology, 2012. http://hdl.handle.net/1721.1/76920