Oxygenated fluid mixture can be used to treat critically ill patients suffering from asphyxia, lung injury, and cardiac arrest. This oxygenated fluid delivered intravenously re-oxygenates the bloodstream, allowing for more time to resuscitate a patient before they suffer brain and/or organ damage. The concentration of the mixture is crucial for treatment as it affects the viscosity of the fluid, which in turn affects how well the fluid mixes with blood and how long it takes for oxygen to diffuse out of it. Evaluating the quality of fluid delivered and characterizing oxygenated fluid mixture at different concentrations was paramount. Since the fluid is a non-Newtonian emulsion, delivering a specific flow rate is challenging due to the following effects: degradation, compressibility, and shear thinning. Therefore, a testing machine was developed to aid in understanding the fluid dynamic behavior of the oxygenated mixture. The quality of the fluid can be assessed through measurement of the volume percentage, particle size distribution, oxygen tension, and rheometry. The data collected from the experiments will serve to create a model for delivering a specific volumetric flow rate of the fluid at atmospheric pressure.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Peña, Kristen Helen
Advisor dc:contributor.advisor
  • Alexander H. Slocum.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/75714
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/75714

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Peña, Kristen Helen. Characterization of an oxygen suspension used for intravenous infusion. Massachusetts Institute of Technology, 2012. http://hdl.handle.net/1721.1/75714