Back to search

Massachusetts Institute of Technology

Nitrogen oxide delivery systems for biological media

Abstract

dc:description.abstract

Elevated levels of nitric oxide (NO) in vivo are associated with a variety of cellular modifications thought to be mutagenic or carcinogenic. These processes are likely mediated by reactive nitrogen species (RNS) such as nitrogen dioxide (NO2) and peroxynitrite formed from the respective reactions of NO with oxygen and superoxide anion. Controlled delivery of these RNS at levels expected to occur in vivo is desirable in studying these processes and their role in the etiology of various diseases. Two delivery systems were developed that provide novel capabilities for steady, quantitative exposure of biological targets to RNS over periods from hours to days. Quantitative models are presented that accurately describe the behavior of both systems. The first system achieves NO concentrations of 0.6-3.0 [mu]M in a stirred, liquid-filled vessel by diffusion from a gas stream through a porous poly(tetrafluoroethylene) membrane. Oxygen, consumed by reaction with NO or by other processes, is supplied by diffusion from a separate gas stream through a loop of poly(dimethylsiloxane) tubing. The adventitious chemistry observed in a prior device for NO delivery [Wang C. Ann Biomed Eng (2003) 31:65-79] is eliminated in the present design, as evidenced by the close match to model predictions of the accumulation rate of nitrite, the stable end product of NO oxidation. The second system delivers NO2 by direct contacting of a stirred liquid with an NO2- containing gas mixture. Accumulation rates of products in the presence and absence of the NO2-reactive substrate 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonate) matched model predictions within 15% for all conditions studied. The predicted steady NO2 concentration in the liquid is on the order of 400 pM, similar to what is expected to be present in extracellular fluids in the presence of 1 [mu]M NO. This system appears to be the first reported with the capability for sustained, quantitative NO2 delivery to suspended cell cultures. Results from initial efforts to test a novel mixing model for bolus delivery of peroxynitrite to agitated solutions imply that the proposed model might accurately describe mixing in bolus delivery experiments with agitation by vortex mixing, but further work is required to validate the model.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Chemical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Skinn, Brian Thomas
Advisor dc:contributor.advisor
  • William M. Deen.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/70107
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/70107

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Skinn, Brian Thomas. Nitrogen oxide delivery systems for biological media. Massachusetts Institute of Technology, 2012. http://hdl.handle.net/1721.1/70107