Back to search

Massachusetts Institute of Technology

Nitrous oxide as a substitute for sulfur hexafluoride in the ANSI/ASHRAE 110 Method of hood performance evaluation

Abstract

dc:description.abstract

The ANSI/ASHRAE 110 Method is the standard test for laboratory hood containment performance. Sulfur hexafluoride is specified as the gas most suitable for this test and is most commonly used. Sulfur hexafluoride use has potential negative environmental repercussions as it is a potent greenhouse gas with a global warming potential 22,800 times greater per mass than CO₂. The purpose of this study is to evaluate nitrous oxide, a much less environmentally destructive tracer gas, as a potential substitute in the ANSI/ASHRAE 110 Method. In accordance with ANSI standards, flow visualization, face velocity, and tracer gas tests were performed on numerous laboratory hoods of varying design. A mannequin was positioned in front of the center of the hood, and a MIRAN SapphlRe was used to measure the presence of each tracer gas. Direct comparisons of the concentrations of the two gases were dominated by a few high concentrations. For this reason, concentrations of both gases were log1O-transformed for statistical analyses. Laboratory hood dimensions and properties were found to affect the relationship between the gases. The hood area of opening and sash height were found to significantly (p<0.001) affect logjo(SF₆/ N₂O). Average face velocity also significantly (p<0.025) affected the log ratio. Neither gas was an adequate indicator of the behavior of the other. The linear best fit of the logs of the concentration ratio had a slope of 0.858, a y-intercept of 0.434, and an R² of 35.9% indicating a poor correlation. For N₂O to qualify as a substitute for SF6 there would need to be a strong correlation between gas concentrations that was consistent independently of hood conditions. This condition was not met. Nitrous oxide was found to not be a suitable substitute for sulfur hexafluoride in the ANSI/ASHRAE 110 Method.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Guffey, Eric J. (Eric Jemison)
Advisor dc:contributor.advisor
  • Leslie Norford.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/68840
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/68840

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Guffey, Eric J. (Eric Jemison). Nitrous oxide as a substitute for sulfur hexafluoride in the ANSI/ASHRAE 110 Method of hood performance evaluation. Massachusetts Institute of Technology, 2011. http://hdl.handle.net/1721.1/68840