Back to search

Massachusetts Institute of Technology

Designing and testing the neutron source deployment system and calibration plan for a dark matter detector

Abstract

dc:description.abstract

In this thesis, we designed and tested a calibration and deployment system for the MiniCLEAN dark matter detector. The deployment system uses a computer controlled winch to lower a canister containing a neutron source into the detector where the neutron source pulses to produce calibration data. The winch then pulls the neutron source back out of the detector. We found that the deployment system position is precise to under 0.05 cm, one tenth of the minimum required precision. We designed a canister that will hold the neutron source during the calibration process. The canister will contain a dielectric gel to thermally and electrically insulate the high voltage electronics and the neutron source from the rest of the detector. We calculated the equilibrium temperature change of the calibration neutron source when it is turned on and found that the temperature increases by 92.6+isi K, corresponding to a rise in the dielectric gel height of 1.501i.9 cm. This temperature change is within the service temperature range of the dielectric gel; however, a more thermally conductive gel could still be used to reduce the temperature increase. We simulate the background external neutrons in MiniCLEAN and find that the addition of an air-filled calibration tube to the basic MiniCLEAN design has little effect on the external neutron background rate. Lastly, we simulate the calibration process in order to determine how long we must calibrate MiniCLEAN in order to obtain the desired 5% statistical precision on measurements of the calibration neutron-induced recoil spectrum. We found that a minimum of 2.48x 106 neutrons are needed to measure the total counts in the region of interest in energy to 5% (corresponding to a pulse mode calibration time of 124 seconds assuming that neutrons are produced at a rate of 105 per second), and 2.02x 107 neutrons are needed to achieve 5% measurements of the energy spectrum with 2 KeVee binning in the region of interest (corresponding to a time of 1005 seconds).

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Physics.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Westerdale, Shawn (Shawn S.)
Advisor dc:contributor.advisor
  • Jocelyn Monroe.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/65538
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/65538

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Westerdale, Shawn (Shawn S.). Designing and testing the neutron source deployment system and calibration plan for a dark matter detector. Massachusetts Institute of Technology, 2011. http://hdl.handle.net/1721.1/65538