Back to search

Massachusetts Institute of Technology

Digital ear scanner : measuring the compliance of the ear

Abstract

dc:description.abstract

This paper seeks to resolve the biggest problem with hearing aids, their physical fit. By digitally scanning the ear canal and taking the dynamics of the ear into account the performance and comfort of a hearing aid can be greatly improved. Current optical techniques for 3-D imaging are too expensive to be implemented in the ear canal for the purpose of custom fitted hearing aids. A new absorption based optical technique is introduced, which is capable of generating three dimensional maps of an ear subjected to a varying pressure. Specifically a hearing aid can be constructed with allowances for the compliance of the ear and the distortions associated with jaw movement. It is shown that the information that can be captured with this new technique will be of value toward improving hearing aids, and that the hearing aid industry is ready to take advantage of a digital scanner. A one dimensional calibration was made, and qualitative 3-D data is shown. The imaging technique was implemented with much lower cost equipment then would be needed by other 3-D techniques such as interferometry. A technique for the laboratory manufacture of brushed on fluorescent balloons was presented that are suitable to be used by this imaging technique to measure the dynamics of the ear. The bulk compliance of a human ear in vitro was measured with a laboratory fabricated balloon.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hernandez-Stewart, Daniel
Advisor dc:contributor.advisor
  • Doug Hart.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/57792
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/57792

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Hernandez-Stewart, Daniel. Digital ear scanner : measuring the compliance of the ear. Massachusetts Institute of Technology, 2010. http://hdl.handle.net/1721.1/57792