Back to search

Massachusetts Institute of Technology

The characterization of a mouse model of transient stroke using ex vivo MR microscopy and in vivo MR imaging

Abstract

dc:description.abstract

Disrupted blood-brain barrier after an ischemic attack can cause vasogenic edema and increase the risk of hemorrhagic transformation. Therefore, early detection and monitoring of BBB damage is important in the pathological understanding and therapeutic treatment of stroke. Currently, MR contrast agents have been widely used in clinics for disease diagnosis and treatment evaluation, and in basic research to achieve better anatomical structure visualization and to understand pathological mechanisms of various human diseases in animal models. Thus, the central theme of this thesis to exploit the use of MR contrast agents in the study of ischemic stroke using both in vivo and ex vivo MR techniques. Specifically, the overall goals of this thesis are twofold: (1) to exploit the multiple relaxation mechanisms and varying tissue-dependent affinities of different MR contrast agents for better structure delineation, tissue differentiation, and image contrast manipulation in magnetic resonance microscopy (MRM) staining, and (2) to develop an MRI technique that employs intrinsic water as a biomarker for qualitative and quantitative monitoring of blood-brain barrier (BBB) integrity alteration in a mouse model of stroke using an intravascular long-circulating MRI contrast agent. Despite the great success of MRM in anatomical studies, MRM images based on intrinsic tissue contrast lack the flexibility and target-specificity offered by conventional histological staining. Therefore, the first focus of this thesis was on the development of MRM staining method by utilizing the different tissue relaxation ability and tissue biophysical/biochemical properties of different MR contrast agents. Two common MR contrast agents, Gd-DTPA and MnCl2 were used in this thesis. The ability of MR contrast agents to increase SNR and enhance image contrast was first tested in a relatively simple in vitro glioma spheroid (diameter ' 400 um) system.

Degree

thesis:*
Department dc:contributor.department
Harvard University--MIT Division of Health Sciences and Technology.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2009

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Huang, Shuning, Ph. D. Massachusetts Institute of Technology
Advisor dc:contributor.advisor
  • Bruce R. Rosen.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/47853
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/47853

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Huang, Shuning, Ph. D. Massachusetts Institute of Technology. The characterization of a mouse model of transient stroke using ex vivo MR microscopy and in vivo MR imaging. Massachusetts Institute of Technology, 2009. http://hdl.handle.net/1721.1/47853