Back to search

Massachusetts Institute of Technology

Improvements in magnetic resonance imaging excitation pulse design

Abstract

dc:description.abstract

This thesis focuses on the design of magnetic resonance imaging (MRI) radio-frequency (RF) excitation pulses, and its primary contributions are made through connections with the novel multiple-system single-output (MSSO) simultaneous sparse approximation problem. The contributions are both conceptual and algorithmic and are validated with simulations, as well as anthropogenic-object-based and in vivo trials on MRI scanners. Excitation pulses are essential to MRI: they excite nuclear spins within a subject that are detected by a resonant coil and then reconstructed into images. Pulses need to be as short as possible due to spin relaxation, tissue heating, and main field inhomogeneity limitations. When magnetic spins are tilted by only a small amount, pulse transmission may be interpreted as depositing energy in a continuous three-dimensional Fourier-like domain along a one-dimensional contour to form an excitation in the spatial domain. Pulse duration is proportional to the length of the contour and inversely proportional to the rate at which it is traversed, and the rate is limited by system gradient hardware restrictions. Joint design of the contour and a corresponding excitation pulse is a difficult and central problem, while determining near-optimal energy deposition once the contour is fixed is significantly easier. We first pose the NP-Hard MSSO problem and formulate greedy and convex relaxation-based algorithms with which to approximately solve it. We find that second-order-cone programming and iteratively-reweighted least squares approaches are practical techniques for solving the relaxed problem and prove that single-vector sparse approximation of a complex-valued vector is an MSSO problem.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2008

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Zelinski, Adam Charles
Advisor dc:contributor.advisor
  • Elfar Adalsteinsson and Vivek K. Goyal.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/45862
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/45862

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Zelinski, Adam Charles. Improvements in magnetic resonance imaging excitation pulse design. Massachusetts Institute of Technology, 2008. http://hdl.handle.net/1721.1/45862