Back to search

Massachusetts Institute of Technology

Experimental study of a high efficiency gyrotron oscillator

Abstract

dc:description.abstract

High power, high frequency gyrotrons used in plasma heating must achieve the highest possible efficiency in order to reduce system size and cost and to minimize thermal and mechanical problems. This thesis presents an experimental study of efficiency enhancement in a 1.5 MW, 110 GHz gyrotron oscillator, which operated at 50 % efficiency with a single-stage depressed collector. We present the design and detailed experimental results of a new low ohmic loss cavity, a four-mirror internal mode converter and a single-stage depressed collector. The low ohmic loss TE22,6 cavity, designated "V-2005", was designed using the code MAGY to have a Q factor of 830, which would be suitable for CW operation in an industrial gyrotron. The cavity was first tested in the axial configuration, in which the output waveguide also serves as the electron beam collector. In 3 microsecond pulsed operation at 97 kV and 40 A, an output power of 1.67 MW at an efficiency of 42 % was obtained without a depressed collector. The V-2005 cavity efficiency exceeds that of the older "V-2003" cavity by 5 percentage points. The enhanced efficiency of the V-2005 cavity may be understood by analyzing the start-up scenario of the cavities. During start-up, the V-2003 cavity suffers from strong mode competition with the TE19,7 mode, resulting in a relatively low efficiency, while the V-2005 cavity has an absence of such mode competition. The experimental mode maps (regions of oscillation vs. magnetic field) obtained for the two cavities are in excellent agreement with the start-up simulations. Following the axial configuration experiments, the experiment was rebuilt with an internal mode converter consisting of a launcher and 4 mirrors, and with a single-stage depressed collector. An output power of 1.5 MW was measured. The internal mode converter operated at 90 % efficiency. When the depressed collector was run at 25 kV, an overall efficiency of 50 % was achieved. An aftercavity interaction (ACI) was investigated as a possible cause of efficiency reduction in the gyrotron.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Physics.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Choi, Eunmi, Ph. D. Massachusetts Institute of Technology
Advisor dc:contributor.advisor
  • Richard J. Temkin.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/45418
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/45418

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
related terms
citation

Choi, Eunmi, Ph. D. Massachusetts Institute of Technology. Experimental study of a high efficiency gyrotron oscillator. Massachusetts Institute of Technology, 2007. http://hdl.handle.net/1721.1/45418