While contempary total knee arthroplasty has been successful in improving the quality of life for those suffering from severe osteoarthritis, the function of these patients has not reached normal levels for their age group. Thus, there is an increasing need to improve total knee arthroplasty techniques to allow patients to function normally. We currently have limited knowledge about how current knee arthroplasties behave in-vivo, but this information could be pivotal in designing new implants and surgical techniques. Therefore, the objective of this work was to develop the Dual Fluoroscopic Imaging System, a non-invasive imaging system capable of measuring in-vivo knee kinematics in all degrees of freedom. This system was used to investigate factors that may affect patient function after total knee arthroplasty. The feasibility of using kinematic data obtained using this system to analyze wear of the polyethylene insert was also explored The system was shown to be repeatable and accurate in determining the pose of the TKA components in all degrees of freedom. Six degree-of-freedom kinematics and articular contact motion were measured in-vivo. Data was obtained for patients with two typical classes of TKA, cruciate-retaining and cruciate-substituting, and the function of conventional implants was compared to that of more recent high flexion designs. In general, no differences were detected between these groups. Further, no factors such as age, weight, PCL management, or kinematics, were found to correlate with flexion capability. Future studies should investigate changes in knee structures from the preoperative state to the postoperative state. Preliminary estimates of polyethylene stresses suggested great potential in using the Dual Fluoroscopic Imaging System in developing a model of in-vivo polyethylene wear.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Suggs, Jeremy F. (Jeremy Floyd), 1976-
Advisor dc:contributor.advisor
  • Guoan Li and Derek Rowell.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/42297
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/42297

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Suggs, Jeremy F. (Jeremy Floyd), 1976-. Investigation of in-vivo total knee arthroplasty biomechanics using a dual fluoroscopic imaging system. Massachusetts Institute of Technology, 2007. http://hdl.handle.net/1721.1/42297