Back to search

Massachusetts Institute of Technology

High Resolution Quantitative Auto-Radiography to determine microscopic distributions of B-10 in neutron capture therapy

Abstract

dc:description.abstract

The success of Boron Neutron Capture Therapy (BNCT) is heavily dependent on the microscopic distribution of B-10 in tissue. High Resolution Quantitative Auto-Radiography (HRQAR) is a potentially valuable analytical tool due to its ability to simultaneously visualize boron distributions and tissue histology. While powerful, the technique has fallen into disuse, largely due to its complexity. HRQAR was reconstituted, and its accuracy was verified with test samples. Numerous improvements were made to make the process easier and more efficient. Permanent staff members at the Institute were trained in the technique, ensuring the continued vitality of HRQAR. The image acquisition equipment and analysis software were modernized, and made more user-friendly. The microdosimetry analysis software was updated to current versions of programming environments and personal computer operating systems. Verification tests were conducted to ensure the continued accuracy of the underlying algorithms. Several experiments were conducted to demonstrate the applications of HRQAR. One focus of current BNCT research is the development of new boron delivery agents, so a potential new compound was compared with a current-generation boron compound. In order to underscore the broader range of utility of HRQAR, another experiment was conducted using the auto-radiography technique as verification of selective microvasculature irradiation.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Harris, Thomas C. (Thomas Cameron)
Advisor dc:contributor.advisor
  • Otto K. Harling and Jeffrey A. Coderre.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/41271
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/41271

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Harris, Thomas C. (Thomas Cameron). High Resolution Quantitative Auto-Radiography to determine microscopic distributions of B-10 in neutron capture therapy. Massachusetts Institute of Technology, 2006. http://hdl.handle.net/1721.1/41271