The Endoblend device concept was developed by a 2.75 design team,of which I was a member; the purpose of the device is to remove tissue laparoscopically. The detailed design of one of its modules, the enclosure module, is the subject of this paper. The Endoblend has the potential to reduce morcellation surgery time from upwards of half an hour to minutes, with reduced risk of the most common complications of nicking the abdomen wall and leaving tissue behind. There are three primary functional requirements of the enclosure module. First, for ease of use, simplicity, and safety the bag and guard in combination must passively feed the tissue into the blades. This was accomplished using, a cone shape to make the bottom of the bag act as an equilibrium state through a gravity feed. Second, the bag must remain intact to prevent tissue from being left behind. To accomplish this it will be shaped with a flat region near the blades so that inflating the bag keeps it away from the blades, and the Ziploc type seal through which the tissue enters will be a double seal with micro beads of cyanocrolate to make a strong permanent seal.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hernandez-Stewart, Daniel
Advisor dc:contributor.advisor
  • Alexander H. Slocum.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/40433
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/40433

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation