Back to search

Massachusetts Institute of Technology

Accuracy of pulsed arterial spin labeling magnetic resonance imaging in the human brain : tag width and timing effects

Abstract

dc:description.abstract

Arterial spin labeling (ASL) is the only non-invasive magnetic resonance imaging (MRI) technique that allows absolute quantification of cerebral blood flow (CBF). It involves using radiofrequency pulses designed to invert the spins of water in arterial blood, effectively creating a magnetic bolus. This inverted blood can be considered an endogenous contrast agent; imaging as it traverses the vascular tree allows CBF measurements. Such types of experiments are especially useful for functional neuro-activation studies and in settings of neuropathology. Two flavors of ASL exist: continuous ASL and pulsed ASL. Pulsed ASL has the advantage of not requiring specialized imaging hardware, and can be performed using standard clinical scanners found in most hospitals. Pulsed ASL techniques, however, may yield inaccurate perfusion values and diminished perfusion sensitivity if appropriate labeling parameters are not chosen, particularly during global challenges such as hypercapnia. In this study, the accuracy of QUIPSS II (Quantitative Imaging of Perfusion using a Single Subtraction - second version) ASL for measuring flow changes during a global flow perturbation (hypercapnia) was assessed.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2007

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Bolar, Divya Sanam
Advisor dc:contributor.advisor
  • Richard D. Hoge and Elfar Adalsteinsson.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/38673
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/38673

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Bolar, Divya Sanam. Accuracy of pulsed arterial spin labeling magnetic resonance imaging in the human brain : tag width and timing effects. Massachusetts Institute of Technology, 2007. http://hdl.handle.net/1721.1/38673