Modelling of a floating piston expander employed in a 10 K cryocooler

Abstract

dc:description.abstract

A single stage of a 3-stage Collins-type cryocooler designed to provide I W of cooling at 10 K was constructed and tested. A single stage of the cryocooler consists of a compressor, a counter-flow heat exchanger, and an expander to expand the working fluid. The work of the expanding cold gas is transmitted up a floating piston and is dissipated by gas flows in and out of a warm volume. Flow through the cold volume is controlled by smart electromagnetic valves. Models were developed to describe the thermodynamic processes that make up the expander cycle. In the first iteration, models were developed to determine the equilibrium states at various points in the cycle by assuming the thermodynamic processes that made up the expander cycle to be quasi-static. These models were used to determine appropriate values of parameters such as the cut-off volume, the recompression volume, and warm end reservoir pressures for expander operation. Experiments were done to determine the efficiency of the floating-piston expander. Tests were also done to determine the characteristics of the heat exchanger and compare them with the design characteristics. Finally, the stage was run as a refrigerator with zero heat-load. It was observed that the quasi-static models did not adequately describe the performance of the expander as most of the processes did not go to equilibrium.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chaudhry, Gunaranjan
Advisor dc:contributor.advisor
  • Joseph L. Smith, Jr.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/33903
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/33903

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Chaudhry, Gunaranjan. Modelling of a floating piston expander employed in a 10 K cryocooler. Massachusetts Institute of Technology, 2005. http://hdl.handle.net/1721.1/33903