Back to search

Massachusetts Institute of Technology

Temperature response of the ultra-high throughput mutational spectrometer

Abstract

dc:description.abstract

The Ultra-High Throughput Mutational Spectrometer is an instrument designed to separate mutant from wild type DNA through capillary electrophoresis. Since this technique uses the melting point of the molecule to distinguish between sequences of base pairs, temperature control is crucial to the success of the device. The purpose of this analysis is to characterize the temperature response of the instrument, taking into account the heat dissipated by the 10,000 capillaries in the system during electrophoresis. Analytical models, finite element analysis, and physical models were used to predict the steady state response of the system to heat generated by capillary electrophoresis. The analytical models estimated a steady state offset of 0.2 K for water at 3.3x 10̄⁴ m³/s (20 L/min) and 1.0 K for water at 6.7x 10̄⁵ m³/s (4.0 L/min) and predicted that the system would reach steady state within several seconds. Finite element analysis determined that the gel inside the capillaries would have a steady state offset of 0.24 K. The physical system, which simulated the Joule heating of the capillaries using an immersion heater, yielded a steady state offset of 0.24 K at 3.3x 10̄⁴ m³/s and 0.65 K at 6.7x 10̄⁵ m³/s, but the settling time in both cases was on the order of 500 s.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Suen, Timothy W. (Timothy Wu)
Advisor dc:contributor.advisor
  • Ian W. Hunter.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/32960
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/32960

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Suen, Timothy W. (Timothy Wu). Temperature response of the ultra-high throughput mutational spectrometer. Massachusetts Institute of Technology, 2005. http://hdl.handle.net/1721.1/32960