The determination of hemocompatibility of a geometrically-altered poly(dimethylsiloxane) surface

Abstract

dc:description.abstract

Bio- and hemocompatibility are some of the driving forces behind medical device creation and materials science in this day and age. An experimental study was performed to test whether a geometrically altered surface of Poly(dimethylsiloxane), or PDMS, was found to be more or less hemocompatible than a flat, unaltered film of PDMS. In this case, the alteration was the addition of micron-scale posts sticking perpendicular to the surface, creating a superhydrophobic "bed of nails" effect. Once the specific altered surfaces were chosen, designed using Photolithography, and manufactured via a polymer casting process, a platelet adhesion assay was developed to assess the relative hemocompatibility of the surface via number of platelets counted on the surface of the altered vs. unaltered PDMS. Apparent contact angles of blood and Platelet-Rich Plasma (PRP) on the surface were also measured. The final instance of this experiment yielded positive results: The geometrically altered surface yielded less debris and platelet adhesion than did the flat PDMS surface, indicating an improvement in the hemocompatibility of PDMS via this process.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Mechanical Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2005

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Becker, Geoffrey A
Advisor dc:contributor.advisor
  • Nam Pyo Suh.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/32879
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/32879

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Becker, Geoffrey A. The determination of hemocompatibility of a geometrically-altered poly(dimethylsiloxane) surface. Massachusetts Institute of Technology, 2005. http://hdl.handle.net/1721.1/32879