Back to search

Massachusetts Institute of Technology

DC powerline communication system using a transmission line transformer for high degree of freedom applications

Abstract

dc:description.abstract

A new type of powerline communication is developed to reduce cable requirements for robotic, electromechanical, and vehicular systems. A DC power bus line connecting a DC power supply to motor drives and sensor units is used for transmitting both data and DC power. Unlike conventional AC powerline communication, the DC power bus provides amenable and predictable noise characteristics and desirable impedance characteristics that allow for large fanout and high bandwidth. First the basic architecture of DC powerline communication is presented, followed by verification of the feasibility of using a DC power bus as a communication medium. A high-fanout modem is then designed using a Guanella type transmission line transformer (TLT). The modem characteristics including high-frequency parasitic dynamics are analyzed, and the overall line impedance and signal attenuation are evaluated as the number of nodes goes to infinity. A prototype DC powerline communication system is then designed, built, and tested. The serial windings and special resonance characteristics of TLT coupled with a capacitor are exploited to minimize attenuation in high fanout systems. As a result the prototype modem can broadcast data to more than 100 nodes simultaneously.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Mechanical Engineering
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wade, Eric R. (Eric Randolph), 1978-
Advisor dc:contributor.advisor
  • Haruhiko H. Asada.

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/27144
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/27144

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Wade, Eric R. (Eric Randolph), 1978-. DC powerline communication system using a transmission line transformer for high degree of freedom applications. Massachusetts Institute of Technology, 2004. http://hdl.handle.net/1721.1/27144