Back to search

Massachusetts Institute of Technology

Analysis and validation of an artifact resistant design for oxygen saturation measurement using photo pletyhsmographic ring sensors

Abstract

dc:description.abstract

Recent advances in continuous noninvasive health monitoring technologies provide clinicians and researchers with a previously unrealistic opportunity for closely tracking the developments and treatments of various pathologies both within and outside of a clinical setting. At the same time, miniaturized, wireless communication technologies have greatly enhanced the transmission of sensor data while reducing the size requirements for traditional, wearable sensors. The synergism of these innovations has led to the development of the Ring Sensor, a miniaturized, telemetric, photo plethysmograph sensor for continuous health monitoring. Previous work on the Ring Sensor has led to significant power savings in regards to data acquisition and transmission. Additionally, early long-term monitoring tests have indicated that the Ring Sensor is capable of acquiring a reliable waveform nearly 30% of the time. However, the utility of the Ring Sensor has remained somewhat limited. This thesis addresses several of the remaining issues associated with the Ring Sensor. The main design consideration associated with the Ring Sensor is achieving minimal power consumption while maintaining high signal quality. To this end, significant effort has been channeled to the development of an appropriate motion artifact model, representing the complex interplay between internal hemodynamics and external influences. Additionally, an artifact resistant, power-efficient, high-speed modulation scheme has been incorporated into the design of the Ring Sensor. It has been shown that this design significantly reduces the amount of data corrupted by motion while also minimizing the power consumed by the LEDs (one of the single largest power consuming elements).

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Dept. of Electrical Engineering and Computer Science.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2004

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Shaltis, Phillip Andrew
Advisor dc:contributor.advisor
  • H. Harry Asada.

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • M.I.T. theses are protected by copyright. They may be viewed from this source for any purpose, but reproduction or distribution in any format is prohibited without written permission. See provided URL for inquiries about permission.
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/27113
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/27113

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Shaltis, Phillip Andrew. Analysis and validation of an artifact resistant design for oxygen saturation measurement using photo pletyhsmographic ring sensors. Massachusetts Institute of Technology, 2004. http://hdl.handle.net/1721.1/27113