dc:description.abstract

Calibration of Magnetic Flux Leakage (MFL) In-line Inspection (ILI) tools is an important part of the overall pipeline integrity management process. Over-called or under-called corrosion features can have significant impacts on safety and resource management. This thesis examines methods for improving the Validation and Calibration processes using Bayesian Inference. The focus is on improving the tolerance that is applied to undug features to optimize the execution of risk-based repairs. A simulated data set was generated, with two separate categories, one which represents tool performance on basic features and another for challenging features. The calculated parameters of [alpha], [beta], and [sigma], were calculated using a Bayesian model leveraging a Markov Chain Monte Carlo simulator. The [sigma] parameter is used to determine the appropriate tolerance to apply and was compared with a [sigma] calculated via the method recommended by API 1163. Results from the example data set show that in challenged situations, the Confidence Level of the tool performance can be increased from 89% to 95% and the mean average error can be decreased using the Bayesian Inference model. Opportunities to use the methods outlined to improve other processes in ILI validation are discussed. By appropriately updating the likelihood used in the Bayesian model with dig data, the tolerance can more accurately represent the undug features and risk management decisions can be conducted accordingly.

Degree

thesis:*
Name thesis:degree_name
Master
Department dc:contributor.department
Massachusetts Institute of Technology. Engineering and Management Program
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lee, Jeffrey Liang.
Advisor dc:contributor.advisor
  • Herbert H. Einstein.

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • MIT theses may be protected by copyright. Please reuse MIT thesis content according to the MIT Libraries Permissions Policy, which is available through the URL provided.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
https://hdl.handle.net/1721.1/132841
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/132841

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Lee, Jeffrey Liang.. Bayesian calibration of in-line inspection tool tolerance. Massachusetts Institute of Technology, 2020. https://hdl.handle.net/1721.1/132841