Back to search

Massachusetts Institute of Technology

Quantifying measurement uncertainties of MIT Research Reactor's new digital nuclear safety system

Abstract

dc:description.abstract

Accurate measurement of reactor power is one of the most important requirements in order to ensure the reliable and safe operation of a nuclear reactor. The MIT research reactor, (MITR-II), currently has outdated analog reactor period and power monitoring instruments that are difficult to read and in need of frequent adjustment. Replacing these old monitors with digital ones is an important step in continuing to ensure MITR-II's reliable and safe operation. Four Mirion DWK 250's, wide-range neutron ux monitors that provides reactor period and power level monitoring, have been assembled and connected to the MITR for parallel testing. Before they can fully replace the existing analog monitors, the accuracy of measurement of the DWK's must be quantified to meet the performance requirements described in the Safety Analysis Report (SAR) and obtain Nuclear Regulatory Commission (NRC) approval. As part of the calibration tests, reactor power measured by the four DWK channels was recorded and compared to the reactor thermal power obtained through calorimetry calculations. The measurement uncertainties of the four DWK channels were quantified by taking into account the statistical uncertainties of data recorded over two separate operating periods in 1 minute intervals after thermal and xenon equilibrium were reached. The reactor neutron power measured by each channel was found to t a normal distribution during steady-state operation, and the 3 values, 99.7% condence level, were found to be less than 1.6% of the average power detected for each DWK indicating each device's high level of precision. The average percent error between DWK and thermal power was determined to be 4% for each DWK, thus a thorough review of calibration procedures should be performed to ensure an accurate indication of reactor power. Furthermore, as the setpoints of the DWK's may be adjusted over the core cycle of the reactor, the relationship between shim blade height and DWK adjustment was also determined by parallel testing and modelling. The adjustment of each of the DWK's over a fuel cycle was found to be minimal.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Nuclear Science and Engineering.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Parus, Rachel (Rachel Elizabeth)
Advisor dc:contributor.advisor
  • Lin-wen Hu.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/119042
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/119042

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Parus, Rachel (Rachel Elizabeth). Quantifying measurement uncertainties of MIT Research Reactor's new digital nuclear safety system. Massachusetts Institute of Technology, 2018. http://hdl.handle.net/1721.1/119042