Influence of motion profile on estimating anatomical elbow joint axes using inertial measurement units

Abstract

dc:description.abstract

Current human motion measurement systems using inertial measurement units (IMUs) typically rely on precise alignment, static calibration poses, or dynamic calibration motions. Muller et al. recently proposed a method for online calibration of the human elbow anatomical joint axes via decomposition of angular velocity measurements. This thesis evaluated this calibration-free method in the context of two motion types. First, the method is evaluated with human-generated motions common to occupational rehabilitation, to investigate activities of daily living (ADLs) as online calibration motions. Second, the method is evaluated with parameterized sinusoidal motion, to investigate amplitudes and frequencies of motions that yield robust axis estimations. It was found for the axis of interest, high on-axis motion and low off-axis motion lead to precise axis estimation and high accuracy estimation of the pronation/supination elbow axis. Further, high off-axis motion and low on-axis motion yielded imprecise axis estimation and inaccurate estimation of both the flexion/extension and pronation/supination elbow axes. A comparative study of different filtering methodologies to the estimation of upper extremity human motion was also performed. Compared to a motion capture truth, the Extended Kalman Filter (EKF) and Unscented Kalman Filter (UKF) were found to perform similarly. An implemented particle filter (PF) was found to perform better than both the EKF and UKF, and on the order of accuracy of a manufacturers black-box algorithm. This work is the first to evaluate a particle filter in the estimation of human motion by inertial sensors. The particle filter was then subject to a sensitivity analysis of the error of its estimated 3D orientation to its underlying algorithm inputs, namely, the accelerometer and magnetometer uncertainties, and number of particles. Recommended operational levels for these parameters are reported. Future work will combine the Muller auto-calibration method, robust IMU orientation filters, and knowledge of appropriate online motions to develop an IMU bias correction method for long periods of measurement.

Degree

thesis:*
Department dc:contributor.department
Massachusetts Institute of Technology. Department of Aeronautics and Astronautics.
Grantor dc:publisher
Massachusetts Institute of Technology
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • McGrath, Timothy M. (Timothy Michael)
Advisor dc:contributor.advisor
  • Leia Stirling.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • MIT theses are protected by copyright. They may be viewed, downloaded, or printed from this source but further reproduction or distribution in any format is prohibited without written permission.
Language dc:language.iso
eng

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1721.1/112472
OAI identifier oai:identifier
oai:dspace.mit.edu:1721.1/112472

Chain of custody

source
Harvested from
MIT
Base URL
dspace.mit.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

McGrath, Timothy M. (Timothy Michael). Influence of motion profile on estimating anatomical elbow joint axes using inertial measurement units. Massachusetts Institute of Technology, 2017. http://hdl.handle.net/1721.1/112472