Brunel University School of Engineering and Design PhD Theses
Engineering aspects of photogrammetric plate measurements: Including the development of a novel interferometer
Abstract
dc:description.abstractTwo different factors involved in the measurement of photogrammetric plates have been studied. A novel interferometer designed to monitor the position of a microscope stage, to be used to measure photogrammetric plates, has been built. The prototype instrument is able to give the position of the stage with a maximum error of less than 200nm. An algorithm has been developed for a motor driven x-y microscope that is able to search a photographic plate automatically for targets, and record their positions. In a trial survey this system was able to measure the positions of the targets on the plates with an uncertainty of approximately 2gm. This result is comparable with the precision that a human operator could achieve using the same equipment, but without the fatigue effect associated with visual observation. Virtually no human interaction is necessary for the system to function.
Degree
thesis:*- Grantor dc:publisher
- Brunel University School of Engineering and Design PhD Theses
- Year dc:date.issued
- 1993
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Severn, Ian
- Advisors dc:contributor.advisor
-
- Spooncer, RC
- Jones, BE
Rights
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Repository record dc:identifier.uri
- http://bura.brunel.ac.uk/handle/2438/5409
- OAI identifier oai:identifier
- oai:bura.brunel.ac.uk:2438/5409