dc:description

The aim of this study was to assess technical feasibility, biocompatibility, and impact on coronary stenosis of a new biodegradable paclitaxel-loaded polylactide stent. Due to high rates of instent restenosis and permanent nature of metal stent implants, synthetic polymers have been proposed as surrogate materials for stents and local delivery systems for drugs. Paclitaxel was shown to inhibit vascular smooth muscle cell proliferation and migration. A novel biodegradable double-helical stent was manufac-tured using controlled expansion of saturated polymers (CESP) for the moulding of a bioresorbable poly(D,L)-lactic acid (PDLLA). A modified balloon catheter for stent deployment was developed according to the mechanical stent properties. Twelve paclitaxel-loaded (170 microg) polylactide stents, 12 unloaded polylactide stents, and 12 316L bare metal stents were deployed in porcine coronary arteries of 36 animals. Six pigs of each group were sacrificed after 3 weeks and 3 months, respectively, for every setting. Drug release kinetics as well as histomorphometrical and histopathologi-cal analyses were performed. A slow paclitaxel release kinetic for more than 2 months and therapeutic tissue concentrations were demonstrated. Coronary stenosis after implantation of paclitaxel-loaded stents (30+/-5% or 49+/-4%) was significantly inhibited compared to unloaded PDLLA stents (65+/-10%, P=0.021 or 71+/-4%, P=0.004) and metal stents (53+/-6% or 68+/-8%, P=0.029 and P=0.020) after 3 weeks or 3 months. Early complete endothelialisation was shown. Nevertheless, a local inflammatory response to the polylactide as a result of the polymer resorption process was observed. This novel polylactide stent showed sufficient mechanic stability, and by incorporation of paclitaxel, a significant potential to reduce restenosis development after vascular intervention was seen.

Degree

thesis:*
Grantor dc:publisher
Publikationsserver der RWTH Aachen University
Year dc:date
2006

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Stein, Andreas
Contributors dc:contributor
  • Dahl, Jürgen vom

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language
ger

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:publications.rwth-aachen.de:61439

Chain of custody

source
Harvested from
RWTH Aachen University
Base URL
publications.rwth-aachen.de/oai2d
Last updated
2026-07-30
Source record
OAI-PMH GetRecord
citation

Stein, Andreas. Langzeituntersuchung zur In-Stent-Restenose eines neuen biodegradierbaren, wirkstoffbeladenen, intravaskulären Polylaktidstents nach Implantation in porcine Koronararterien. Publikationsserver der RWTH Aachen University, 2006. https://publications.rwth-aachen.de/record/61439