Back to search

Publikationsserver der RWTH Aachen University

Vollständige iterative Rekonstruktion von dreidimensionalen Positronen-Emissions-Tomogrammen unter Einsatz einer speicherresidenten Systemmatrix auf Single- und Multiprozessor-Systemen

Abstract

dc:description

Positron emission tomography (PET) is a modern medical diagnostic procedure, which enables non invasive views of the metabolism of living organisms. Thereby it visualises also malfunctions which are characteristic for neurological, cardiological and oncological illnesses. For this purpose, radioactive, positron emitting tracers are injected into the patient. The emitted radiation is measured by detector systems and images of the activity distribution are calculated by reconstruction procedures. Newer, high sensitive PET devices with 3D detector systems pose substantial, so far yet unaccomplishable demands to the reconstruction programs because of the complexity and size of data. In this work a procedure is presented, with which the reconstruction problem is represented as linear equation system (LES). Methods are developed and implemented, in order to calculate the coefficient matrix of the LES exactly as well as efficiently and to compress it so extensively, that it can be stored completely in memory. Here the LES can be solved by means of a fast converging, iterative approximation method in short computation time. In addition, the well-established Ordered-Subset-MLEM algorithm is parallelized, the subset partitioning is improved, and the handling sequence of the subsets is optimized. This method of reconstruction is superior to known procedures regarding image quality and computation time.

Degree

thesis:*
Grantor dc:publisher
Publikationsserver der RWTH Aachen University
Year dc:date
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kehren, Frank
Contributors dc:contributor
  • Oberschelp, Walter

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • info:eu-repo/semantics/openAccess
Language dc:language
ger

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:publications.rwth-aachen.de:61010

Chain of custody

source
Harvested from
RWTH Aachen University
Base URL
publications.rwth-aachen.de/oai2d
Last updated
2026-07-30
Source record
OAI-PMH GetRecord
citation

Kehren, Frank. Vollständige iterative Rekonstruktion von dreidimensionalen Positronen-Emissions-Tomogrammen unter Einsatz einer speicherresidenten Systemmatrix auf Single- und Multiprozessor-Systemen. Publikationsserver der RWTH Aachen University, 2001. https://publications.rwth-aachen.de/record/61010